Page 8

GE Newsletter June 2017

Application Spotlight Appendix - Instrument Manufacturers References Typically, with each Newsletter article we include an “Instrument News” section. Seeing that “High TDS” applications are such a popular topic in ICP spectrometry, we thought it would be valuable to list several ICP manufacturer application notes addressing this topic. This section provides a list of application notes that supplement the information presented here. Addition details from each manufacturer highlight what adjustments can be made to the ICP operating parameters to improve ICP performance. This section may also be helpful if you are in the market for a new ICP-OES or ICP-MS instrument. Agilent 5100/5110 ICP-OES: 1. Publication # 5991-4854EN, “Benefits of a vertically oriented torch - fast, accurate results, even for your toughest samples.” 2014 2. Publication # 5991-7914EN, “Analysis of Four Elements (Ca, Mg, Si, Sr) in Brine Using the Agilent 5100 ICP-OES.” 2017 Agilent 7900 ICP-MS: 1. Publication # 5991-4257EN, “Performance of Agilent 7900 ICP-MS with UHMI for high salt matrix analysis.” 2014 Analytik Jena PQ 9000 ICP-OES: 1. Analytik Jena Application Note, "Brine Analysis by HR ICP-OES on PlasmaQuant PQ 9000 Elite." 2014 2. Analytik Jena Application Note, "Direct Sea Water Analysis by HR ICP-OES." 2015 Horiba Ultima 2 ICP-AES: 1. Application Note 48 “Brine Analysis with the ULTIMA 2 ICP-AES.” PerkinElmer Avio and Optima ICP-OES: 1. PerkinElmer Application Note # 012881-01, “Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES.” 2016 2. PerkinElmer Application Note # 009935-01, “ICP-OES Analysis of FeCr Alloys Prepared by Sodium Peroxide Fusion.” 2011 PerkinElmer NexION ICP-MS: 1. PerkinElmer Product Note # 012394-01, “All Matrix Solution System for the NexION ICP-MS.” 2015 SPECTRO Arcos II ICP-OES: 1. SPECTRO ICP Report 62, “Analysis of 200 g/L NaCl-Solutions by ICP-OES with Radial Plasma Observation.” Shimadzu 9800 ICP-AES: 1. Shimadzu Application News # SSI-ICP-003, “Analysis of Highly Mineralized Aqueous Solutions by ICP-AES, a Non-dilution Method with Multi-wavelength Calibration for Major, Minor and Trace Elements.” 2016 Teledyne Prodigy 7 ICP-OES: 1. Teledyne Leeman Labs Application Note AN 1305, “U.S. EPA SW-846 Method 6010C Using the Prodigy7 HighDispersion ICP Introduction.” 2015 Thermo iCAP 7000 Series ICP-OES: 1. Thermo Fisher Scientific Application Note # 43185, “Analysis of Trace Elements in Seawater Using the Thermo Scientific iCAP 7000 Series ICP-OES Duo.” 2016 Thermo iCAP Q, RQ and TQ ICP-MS 1. Thermo Fisher Scientific Technical Note # 43202, “Analysis of High Matrix Samples using Argon Gas Dilution with the Thermo Scientific iCAP Q ICP-MS.” 2016 2. Thermo Fisher Scientific Technical Note # 43359, “Typical Performance of the Thermo Scientific iCAP RQ ICP-MS for Ultratrace Elemental Analysis.” 2016 3. Thermo Fisher Scientific Technical Note # 43404, “Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific iCAP TQ ICP-MS.” 2017 www.geicp.com Glass Expansion Newsletter | Issue 43 8


GE Newsletter June 2017
To see the actual publication please follow the link above